Scope of delivery |
sensor pairs, calculation unit, Power supply
|
Minimum number of sensor pairs connected to a system |
2 |
Maximum number of sensor pairs connected to a system |
16 |
Temperature Independent Measurement |
Hot or Cold1 dimension |
Pyrometer Integration |
Integration of standard wtl third party Pyrometer1 |
Sensor housing material options |
Aluminum alloy or Stainless Steel according to customer's choice |
Process Unit Delivery |
Switch cabinet or protected housing9 |
Protection |
IP20 (switch cabinet), IP68 (protected housing), IP68/IP69K (radar sensor unit) |
Certification |
CE |
Power |
230 VAC / 50 Hz or
110 VAC/ 60 Hz for U.S. Market available
|
Power consumption |
~500 Watt (with 16 Sensors) |
Measurement principle |
FMCW-Radar |
Radar Sensor |
SiGe RadarChip |
Band |
122 GHz-band ISM, 0,9 GHz bandwidth; further bandwidth on request |
Data fusion |
High-performance embedded system |
Communication |
Modbus TCP
TCP/IP, REST or MQTT available in the COM service package
|
Trigger modes for measurement |
non triggered, triggered by PLC, IT2 or self-triggered |
PLC Interface |
Modbus TCP/IP |
Alternative Communication Interface2 |
MQTT3 with QoS2, REST4 or a raw TCP/IP5 |
Additional Communication Capabilities2 |
Receive information for a measurement e.g. reference values, trigger signals, material identification and more |
Monitoring Interface6 |
WebSockets or MQTT3 with QoS 2 |
Monitoring Capabilities6 |
Internal information of Sensors and Processing Unit, their Metadata and measurement related information |
Interface Encryption |
Transport Layer Security (TLS), additional RFC 7519 Industry Standard7 |
Web Configuration Dashboard |
Embedded Web Application for observing and calibrating the Solution |
Browser Compatibility |
Chrome/Edge8 |
Sensor Measurement rate |
50 Hz default |